Main finding: At 3 years, mean change in spherical equivalent refraction and axial length was 59% (-0.73 dioptres) and 52% (0.32mm) less than in the control group respectively.
Study characteristics:
Name: “A 3-year Randomized Clinical Trial of MiSight Lenses for Myopia Control”
Purpose: To evaluate the effectiveness of MiSight soft contact lenses in juvenile-onset myopic progression
Type: Randomised controlled Trial
Condition: Myopia
Year results published: 2019
Participants: Aged 8-12 years old, myopia
-spherical equivalent refraction: −0.75 to −4.00 D
-astigmatism <1.00 D
-No prior contact lens wear
n=109 patients
Intervention:
Group 1: MiSight 1-day contact lens daily
Group 2: Control contact lens
There were no serious ocular adverse events reported.
Outcome measure
MiSight contact lens
Clear contact lens
Difference in outcome
Mean change in spherical equivalent refraction
-1.24D
-0.51D
-0.73D (59%)
Mean change in axial length
0.62mm
0.30mm
0.32mm
Share This Article :
Please provide feedback on content published. Thank you.